Suntuf Installation Guide and Tips

Suntuf Installation Guide

Suntuf Installation Guide and Tips

Installation of Suntuf is easy when you plan the job right!

Just keep our top installation tips in mind before you start to install your new Suntuf product.

Fall, pitch or slope?

Firstly, fall.  A five degree fall is recommended as minimum for ensuring that it does not leak, remains clean and maintains structural integrity.

A good slope helps to move water off the roof.  Flat roofs are more prone to water pooling (in sever cases) and leaking when the water cannot be dispersed quick enough. Designing in a good fall is always important at the start of a project.

All polycarbonate sheets are transparent (you can see through them) or translucent (light comes through them but you can’t see through them clearly). This means that you will be able to see, to some degree, what is on top of them.  Leaves, dirt, dust, bird droppings, etc.  The better the fall on your roof the easier it will be for these things to fall off or wash off.

Most manufactures recommend a minimum of 5 degrees (or 8.8%) fall.  This means for every metre the sheet runs horizontally it should drop about 88 mm.

 

Spans – Where you will need your purlins

All profiled polycarbonate sheets require purlins or battens for fixing.  These structural lengths of timber or metal run perpendicular to the fall of the sheet – see the below image for a visual explanation.  Different profiles have different spanning capabilities.  The below spans are given for a standard N3 wind rating, if you are in a high wind area you may require additional fixings and structure – call us to discuss.

Corrugated 800 mm End Spans and  1000 mm Mid Spans

Greca 900 mm End Spans and 1200 mm  Mid Spans

Trimdek 900 mm End Spans and 1200 mm  Mid Spans

Suntuf Installation Guide Purlin Spacings

Curving

Suntuf polycarbonate sheets can be cold curved.  The shape of the sheet (the profile) will determine how tightly it can curve.  If you want to determine if a sheet can cold curve to to suit your structure you will need to know the following information:

The chord: the horizontal distance from one side of the roof to the other.

The height: the vertical distance from the imaginary horizontal chord line to the top of the apex.

See the below diagram.

 

Suntuf Installation Guide Cold Curving polycarbonate roofing

Cutting

We can cut sheets to length for you free of charge.  Otherwise, sheets can be cut using a fine tooth circular saw, a jigsaw, or even with a good pair of scissors.  When using power tools you will need to clamp the sheet as close to the end as possible to stop vibration. Remember to allow for some overhang to ensure that water from the sheet will fall into the gutter and not onto your structure.

Movement

All materials expand and contract when they heat up and cool down, and polycarbonates move more than most roofing materials. This means that it is important to allow the sheet room to move a little after it has been installed.  This is easily done by following a few rules.

Firstly, drill an over-sized hole in the sheet for the screw fixing. Both Clearfix and OneShot branded screws have cutters embedded on the screw to save you time in completing this step – they cut the hole when you put the screw in.

Secondly, by allowing a small gap between the ends of sheets and where they might come up against another object – like a wall fascia. This isn’t as important on the barge sides as the majority of the expansion will occur along the length of the sheet.

Silicons

As a rule – they are not recommended.  Silicons can act as an adhesive which can stop the sheet from moving (see above).  Some silicons can also affect the chemicals in the sheet which protect it from UV radiation.  If you can’t avoid it use a neutral cure or non-acidic silicon sparingly.  Be sure not to put it along the length of the sheet where you will see the most expansions and contraction.

Accessories

Purlin tape can be used to stop creaking of the sheet with expansion and contraction. As the name suggests it is applied to the purlin prior to installing the sheet, and acts as  buffer.  It is particularly useful with painted purlins, where in hot weather the paint can become tacky and cause the sheet to stick and make more noise as it expands and contracts.

Flashings are used to seal the edges of the sheet.. There are a few different types that are common. Ridge capping is used to flash a gable at the peak of the roof. Barge Flashing is used on the sides of the structure to cover the edges of the sheet and sometimes protect the timber structure underneath. And Apron Flashing is used to seal between a vertical wall or fascia and the roof itself.  You can get a number of these flashings in polycarbonate or have them manufactured in metal.

Suntuf Flat Barge Flashing

Suntuf barge flashing installation

Suntuf Flat Ridge Capping

Ridge capping Suntuf Installation guide

Suntuf Profiled Ridge Capping

Suntuf Greca Ridge Capping installation  Ridge Capping Flashing installation Polycarbonate

Suntuf Profiled Apron FlashingCorrugated Apron Flashing Installation SuntufGreca Apron Flashing Suntuf Polycarbonate installation

Infills can be used between the sheet and any flashings or structure for weatherproofing.  Infills are available in the standard roofing profiles: Corrugated, Greca or Trimdek (5-rib).  An infill may be used between the the sheet and the Apron flashing on the top edge of the roof, or between the purlin and the sheet at the gutter end of the sheet to weather seal.

Infills Suntuf Polycarbonate

Infill Polycarbonate Install

Back channels are normally used when the top end of the sheet is being installed directly underneath a gutter.  A metal channel C- section is combined with foam to seal the end of the sheet in these circumstances.

 Back Channel Installation PolycarbonateScrews

We supply 2 brands of screws; Clearfix or Oneshot.

One Shot screws are available in either a timber T17 or a metal Tek.  When screwing into hardwood or larger gauge metals they are the screw of choice.  They come with a cutter to pre-cut a 10 mm expansion hole into the polycarbonate sheet, and a soft rubber washer to seal the large hole.

The Clearfix screw is a  dual purpose head – suitable for both timber and metal installations. They also come with a cutter and washer to suit polycarbonate.

Storage

Store Suntuf on a flat surface away from direct light and moisture.

Cleaning

Warm soapy water, with a soft sponge.  Be careful not to scratch the sheet. Rinse well.  Don’t use other chemicals.

Installing the Polycarbonate

The standard installation guide covers the actual fixing of the sheets well.  Make sure you read it.  Find it here… Suntuf Installation Guide.

Allow for the sheet to overhang the lower purlin by 50 mm.

Sheets will arrive with labels showing ‘This side up’ and it is very important to install the sheets in the correct orientation. A UV layer on the polycarbonate, protect the sheet from premature breakdown.  Put it up the wrong way and you will experience decreased life for your polycarbonate.

When screwing the sheets keep the screw straight to ensure weather seal of washer. Don’t over-tighten the screws.  If you’re not using the branded screw mentioned above, be sure to pre-drill a 10 mm holes in sheet.

Install the first sheet screwing along the ‘lower (gutter) purlin’ from the outside (Barge side) towards the middle of the structure. Screw every other corrugation along the bottom purlin.  Install the sheets without stress – that is; don’t pull, tension or twist the sheets.

Next move up to the next purlin screwing across the sheet in the same direction.  Place screws as per the below diagram and continue this for all the ‘internal purlins’ or ‘mid purlins’.

Finally, Screw along the top ‘upper purlin’ placing a screw every second corrugation.

Suntuf Polycarbonate screwing placement installation

Move along to the next sheet.  Use one corrugation side lap, ensuring the lap is against the primary direction of wind/rain.  Finish the job by installing any required flashings.  Don’t forget to remove any stickers or tapes from the sheet.

Thanks for looking at our Suntuf Installation Guide and happy installing!

 

 

 

 

About the author

Polycarbonate Roofing

Related posts
Laserlite Installation guide
Laserlite Multiwall Installation Guide with Tips
March 4, 2020
Hail resistant polycarbonate sheets improved impact resistance extra strong
Hail resistant polycarbonate sheets
October 4, 2018
Suntuf Sunlite Twinwall Installation guide and tips
May 24, 2017
232 Comments
  1. Reply
    September 7, 2016 at 4:39 am
    Jesse

    What about valleys?

    • Reply
      October 25, 2016 at 12:38 pm
      Polycarbonate Roofing

      Hi Jesse

      Yes, valley fixing is one method… generally we would recommend crest as per a standard roof install! See my response to Roy for a full rundown.

  2. Reply
    September 9, 2016 at 12:35 am
    Roy

    I am building a steel work shop/ shed,6×5 metres. On the north facing gable end I am going to put a horizontal 6m sheet of diffused ice and on the south side a 6 m horizontal sheet of clear (to maximise light)
    With your years of experience , please let me know the best way to fix to the steel studs
    Regards
    Novice shed clad der
    Roy

    • Reply
      October 25, 2016 at 12:37 pm
      Polycarbonate Roofing

      Hi Roy

      Thanks for the question.

      I assume that you will be running the ribs on the sheet vertically, for the gable end. If not, you may find that dust/dirt will build up in the ribs of the sheet as water will not easily wash them off. But for installing, you can fix the sheet via various methods:
      1. Crest fixing – you can use the normal polycarbonate compatible screw (e.g. Clearfix or OneShot) for steel. These include a cutter which cuts a 10 mm hole in the sheet as you insert the screw. This allows for expansion and contraction in the sheet.
      2. Valley Fixing – you can also screw through the valleys of the sheet. Generally speaking this is a less watertight method, but for a vertical wall this is less of a problem. A few things to note if you choose to do this. The standard polycarbonate screws that have cutters are no good. The cutters will get in the way. You MUST pre-drill a 10 mm expansion hole. you also need to take care not to pin the sheet to the frame by over tightening.

      I hope that this provides some assistance to you.

      Cheers
      Richard

  3. Reply
    October 25, 2016 at 12:52 pm
    Rick

    What side of the sheet should face up?

    • Reply
      October 25, 2016 at 12:54 pm
      Polycarbonate Roofing

      Hi Rick

      Thanks for the question. All sheets will be clearly marked with a label saying THIS SIDE TO THE SUN, this is very important to stop the sheet breaking down prematurely.

      Richard

  4. Reply
    November 7, 2016 at 3:53 pm
    Kev

    Can you please advise me how to cut the trim deck roofing, we have a shed and need to add on to it to protect gardening equipment?

    • Reply
      November 7, 2016 at 4:17 pm
      Polycarbonate Roofing

      Hi Kev

      Thanks for the question.

      We can cut sheets to length for you free of charge. Simple advise us of your requirements when you order.  

      Otherwise, sheets can be cut using a fine tooth circular saw, a jigsaw, or even with a good pair of scissors (if you are only cutting small sections or the odd sheet).  When using power tools you will need to clamp the sheet as close to the end as possible to stop vibration, and it can often be easier to cut a few sheets at a time. Remember to allow for some overhang to ensure that water from the sheet will fall into the gutter and not onto your structure.

      Thanks

  5. Reply
    November 9, 2016 at 7:08 pm
    Levi

    Can I install lights legally under the this fitted poly roof?

    • Reply
      November 14, 2016 at 1:08 pm
      Polycarbonate Roofing

      Hi Levi

      I have never hear of this being a problem… Usually the roofing sits on top of timber rafters and purlins you would need to fix the light to some of this structure. Pending the type of bulb and the heat that it gives off you may need to consider the distance from the light to the polycarbonate. Otherwise, your electrician should be able to advise you further.

      Hope this helps
      Polycarbonate Roofing

  6. Reply
    November 14, 2016 at 11:54 am
    Justin

    Hi, I want to use the 10mm twin wall sheeting to enclose a balcony on a 1st floor. What are the installation guidelines with regards to wind and distances needed in between fastening.

    thanks

    • Reply
      November 14, 2016 at 1:49 pm
      Polycarbonate Roofing

      Hi Justin

      A full answer to the question would require information on your local wind rating. For standard (up to N3 rating) fixings are generally recommended at 800 centers (through the Aluminium H bars). Under high wind situations it may be necessary to place a polycarbonate roofing screw directly through the center of the sheet. IF you thin you may need – please contact us for a copy of the high wind installation guide.

      Cheers
      Polycarbonate Roofing

  7. Reply
    November 14, 2016 at 12:01 pm
    Mike

    I am building a 20m x 5m carport/side verandah structure on the side of my house. We want to include some 100% block for full shade via corrugated Zincalume sheets as well as some Suntuf sheeting. Even allowing for doors, windows etc…. do you have any guidelines for the best way to produce an even diffused light effect? Is it best to keep an even spacing of Suntuf sheets (1:1, 2:1 or 3:1) within the structure, or focus more on spacing to suit windows etc… Thank you.

    • Reply
      November 14, 2016 at 2:31 pm
      Polycarbonate Roofing

      Hi Mike

      Thanks for the question. There is no direct answer to this question other than to point out a few considerations:
      1. The more polycarbonate the more light… it will depend on the balance that you are looking for.
      2. When considering light diffusion colour plays a large part – colours like opal will scatter the light coming through the sheets and give a more even spread of light. Clear may let more light through, but you will see clear shadow lines on the ground below outlining the joining of metal to polycarbonate…
      3. Many people use polycarbonate over windows or doors to allow light to flow into other areas as needed and find this practical – it may not give an ‘even’ light to the whole area however.

      I trust this helps somewhat.

      Cheers
      Polycarbonate Roofing

  8. Reply
    November 23, 2016 at 1:44 pm
    michael

    Hello, Got a problem you may be able to solve for me. I have recently replaced the polycarbonate roofing sheets (greca profile) on my pergola which hang over guttering, but I am now noticing some water creeping back up from the ends that overhangs the gutter and drop onto the floor below. Depending on the the strength of the rain it can become quite annoying. Is there a solution to stop the water creeping back and drop straight into the gutter as intended. Any ideas would be appreciated.

    • Reply
      November 23, 2016 at 2:48 pm
      Polycarbonate Roofing

      Hi Michael

      Thanks for the question. I would assume that the gradient (fall) on the roof is a bit low. You have a few options…

      1. Increase the fall on the roof. This would require quite some effort, but it does have the added benefit of improving the ‘self cleaning’ of the sheets. This means that when it rains, or the wind blows, dirt/leaves etc are more likely to wash off the sheeting making it look more appealing. If that sounds a bit too hard…
      2. Depending on the distance from the end of your sheeting to the end purlin, you could use infills under the sheeting to stop the water creep. Obviously it will keep creeping until it hits the infill – this may or may not help. Finally…
      3. You could add a small amount of silicon to the valley section of the roofing at the very end of the sheet in the gutter. This will effectively create a ‘drip edge’ which will help to stop the water creep. If you do decide to use this option – remember the following: use a neutral cure (Polycarbonate friendly) silicon, only apply the silicon to the sheet, i.e. don’t use it as an adhesive to stick the sheet down to the purlin. It is important that you allow the sheet to expand and contract.

      I trust that this helps.

      Regards
      Polycarbonate Roofing

  9. Reply
    November 28, 2016 at 3:18 am
    Keith Davis

    I am building a small shed 8′ X 10′ with a 1′ rise for a 2′ run. Should I install drip edge along either the sides or bottom of the roof?

    • Reply
      November 28, 2016 at 9:37 am
      Polycarbonate Roofing

      Hi Keith

      Thanks for the question.

      If I am understanding you correctly, you have a 1 foot fall for every 2 foot run (horizontal distance traveled). This would give you a fall of about 26 degrees. With a good fall like this you should not require a drip edge… the water is very unlikely to travel back up the under side of the sheet. I trust this answers your question!

      Thanks
      Polycarbonate Roofing.

  10. Reply
    November 30, 2016 at 7:42 pm
    Richard

    Hi, I have an old flue in my metal roof that I want to remove and replace with a clear sheet to let some more light into my living room.

    Are any of your products suitable and can you let me know how to install them so that i doesn’t leak?

    Thanks,

    Richard

    • Reply
      December 1, 2016 at 11:56 am
      Polycarbonate Roofing

      Hi Richard

      I assume that you are talking about a ‘chimney’ flue coming through the roof. It is not clear if the flue is leaving the roof from within the wall of the house or outside, from a patio roof. If internally… this is not usually done as there is always a ceiling under the roofing, which of course would stop any light getting into the rooms of the house… effectively just lighting up the ceiling cavity. This would normally be achieved with a skylight which effectively creates a tunnel from the roof through the ceiling cavity to the ceiling. This ‘tunnel’ keep outs heat/vermin/bugs etc from the ceiling cavity getting into the house. In some cases the cavity may be built in. This may be a consideration…?

      Otherwise, as for waterproofing… the best solution where possible is always to replace a whole sheet so that the polycarbonate would run from the flashing on the top edge of the roof to the gutter in a continuous length. In this case you can lap the polycarbonate OVER on BOTH sides of the metal. As per usual you would need to pre-drill the polycarbonate, use a polycarbonate compatible washer and screw normally through the metal sheet on the lap.

      I trust that this helps, don’t hesitate to give us a call if you have further questions.

      Regards
      Polycarbonate Roofing

  11. Reply
    December 11, 2016 at 12:23 pm
    Ray

    Hello I have had a pergla plastice roof replaced & it leaks or drips water from some of the screws should this happen

    • Reply
      December 14, 2016 at 9:22 am
      Polycarbonate Roofing

      Hi Ray

      No, like any roofing, it shouldn’t leak if it has been installed correctly. It may just mean that some of the screws have not been put in straight, meaning that the washer isn’t sitting flush and making contact the full way around. I would start by having a look at the screws.

      Regards
      Polycarbonate Roofing.

  12. Reply
    January 15, 2017 at 5:50 pm
    Ron

    Hi was is the correct overlap a corner please the veranda is in the corner of the house and thus 2 sheets will overlap at 90 degrees

    • Reply
      January 17, 2017 at 11:39 am
      Polycarbonate Roofing

      Hi Ron

      Thanks for the question.

      With Corrugated roof sheets (or any profiled sheet for that matter), when you are working around a corner the sheets will not overlap. You will be creating either a ‘hip’ or a ‘valley’ depending on if it is an external or internal corner. In either case you would need to cut the sheets at an angle and then use a flashing for water proofing. You would be best to speak to a local metal fabricator for these flashings.

      Regards
      Polycarbonate Roofing.

  13. Reply
    January 18, 2017 at 8:55 am
    Heath Souter

    Hi, I have a carport with a colorbond fence 1800 high, affixed to the carport posts, I need to fill in the gap at the top of the fence (about 400mm) and plan on using some clear polycarb sheeting (Suntuf greca profile, ridges will be horizontal) what is the best way to seal the top and bottom? I was thinking of using some colorbond flashing. the sheets themselves will be screwed to the carport posts using polycarb roofing screws.

    • Reply
      January 19, 2017 at 12:33 pm
      Polycarbonate Roofing

      Hi Heath

      Thanks for the question.

      Yes some custom flashing would be the best way to seal this. Be aware that there maybe a bit of dirt/dust visible on the corrugations of the sheets as it can build up a little when running the sheets horizontally. Be sure to face the UV side out, otherwise it can break down prematurely.

      Good luck
      Polycarbonate Roofing.

  14. Reply
    January 20, 2017 at 7:06 am
    Bruce

    Do I wait to secure the top row of screws onto the roofing sheets until I pt on the ridge cap? So the ridge cap and roofing is screwed in at the same time?

    • Reply
      January 20, 2017 at 10:03 am
      Polycarbonate Roofing

      Hi Bruce

      Thanks for the question.

      It could be done either way, if you screw the sheets first the screw head may make the flashing sit a little proud, a foal infill usually overcomes this. If you screw them both at once you need to ensure that the polycarbonate is still pre-drilled with an oversize hole for the screw to allow for expansion and contraction.

      If you use a polycarbonate flashing you can use the standard screw with the cutter. The cutter will cut bother the flashing and the polycarbonate.

      If you us a metal flashing, you may find that you need to remove the cutter from the screw (oneshot) or find a screw without a cutter. in this case you would need to take the extra step of pre-drilling the polycarbonate sheet.

      I hope this helps.

      Cheers
      Polycarbonate Roofing.

  15. Reply
    January 27, 2017 at 4:29 pm
    Ted

    How do you fix the end panels to the facia when installing under a gutter. and does it matter which way the “C” section goes ie wide side up or down?

    • Reply
      February 2, 2017 at 4:22 pm
      Polycarbonate Roofing

      Hi Ted

      The ‘back channel’ is usually pinned against the fascia with the long side on the top. It should be used with foam for waterproofing and to allow for some expansion and contraction. There are numerous ways in which you could hold the channel in place… rivet,screw into fascia a dab of silicon etc.

      I trust this helps

      Polycarbonate Roofing

  16. Reply
    February 18, 2017 at 7:59 am
    Michelle

    If you can’t walk on the polycarbonate sheets how do you climb up to fit and fix the ridge capping to a hip roof?

    Thank you 🙂

    • Reply
      February 21, 2017 at 3:58 pm
      Polycarbonate Roofing

      Hi Michelle

      Walking directly on polycarbonate sheeting is not recommended. In situations where you need to get across the polycarbonate it is recommended that you use a “crawl board” or in other words a plank! It should span across a few of the supports underneath the roofing to spread the load. Be sure to take care not to scratch the sheets too – you can use a blanket underneath.

      I trust this helps.

      Regards
      Polycarbonate Roofing team

  17. Reply
    February 18, 2017 at 1:54 pm
    James

    I am fixing 8 Sunglaze sheets to a pergola roof. I have all the joiner sections for the 7 mid sections, but how are the sides of the two end pieces sealed?

    • Reply
      February 21, 2017 at 4:07 pm
      Polycarbonate Roofing

      Hi James

      Where a full sheet is used you can use the joiner again. If you are cutting the sheet a few angles, one under and one above the sheet is one method. Then the angles can be screw into place to secure the edge of the sheet.

      Kind regards
      Polycarbonate Roofing

  18. Reply
    February 18, 2017 at 2:19 pm
    James

    I have know worked that one out

  19. Reply
    April 5, 2017 at 9:58 pm
    william luke

    Hi.. Ive just installed the roofing yesterday, and today there are cracks running the full length. These cracks are only on the underside. They are not the whole way through. I can defininately catch my finger nail on the cracks. They are on most of the ridges that i have screwed. So im thinking over tightened. But i see they are on some ridges not screwed, but i cant catch my finger nail on these oned. They look like cracks, but dont seem to be.

    • Reply
      April 20, 2017 at 12:45 pm
      Polycarbonate Roofing

      Hi William

      Thanks for the comment. Certainly doesn’t sound right! Over tightening isn’t normally a concern (as the sheets will bounce back into place once backed-off). I think your best course of action would be to contact someone from where you purchased the product.

      Good luck!
      Polycarbonate Roofing

  20. Reply
    April 8, 2017 at 8:26 am
    John

    Just a thought. On the Grandkids cubby house ( used to be our garden shed but, what do you do?) a full size gutter wasn,t needed but a cover of some description was needed along the bottom edge of roof panels so various heads weren,t cut. Ended up fitting a strip of Back Channel minus the infill and sloping it away to one end. Looks good, no sharp edges. For the limited amount of water its fine.

  21. Reply
    April 8, 2017 at 11:15 am
    Craig

    I am roofing a pergola attached to a 2 story house. How should I seal the flashing against the rendered wall?

    • Reply
      April 20, 2017 at 12:39 pm
      Polycarbonate Roofing

      Hi Craig

      Thanks for your question. I assume that you are using an apron flashing? This would normally be sealed with silicon in most cases. I trust this helps.

      The team at Polycarbonate Roofing

  22. Reply
    April 21, 2017 at 4:54 pm
    Quentin

    Hi
    What overlap is required when the sheeting is between colorsteel up the roof.

    Thanks

    • Reply
      April 27, 2017 at 8:23 am
      Polycarbonate Roofing

      Kia Ora Quentin

      Thanks for your question. Side laps are standard, that is one and a half ribs for corrugated, one rib for Greca profile and one rib for Trimdek.

      If you are referring to end laps (as i suspect you are), you are normally recommended to lap some where between 200-300 mm. This means 100-150 each side of the row of lap screws (you always need to make sure that the lap is over a support. We have covered this (with a helpful picture) in another post see the link below:

      http://polycarbonate.com.au/polycarbonate-sheets-longer-3-6-m/

      I trust this helps!
      Polycarbonate Roofing

  23. Reply
    April 25, 2017 at 4:48 pm
    Julie

    I would like to install panels onto an existing aluminum pergola which is attached to my house. The structure has 5 rafter beams which are 2 inch by 6.5 inch set 22 inches apart supporting 48 purlins which are 1.5 inches square set 1.5 inches apart. This is attached to the house on two sides with pillars at the outside corners. The structure has no pitch to allow for water runoff. Do you think that I would be able to use your product to cover the existing structure? Keeping in mind the beams and purlins are hollow, how would you advise attaching panels to the aluminum?

    • Reply
      April 27, 2017 at 9:31 am
      Polycarbonate Roofing

      Hi Julie

      Thank you for your question.

      There are a few considerations here! The short answer is yes, it could be used – but there would be a few compromises:
      1. Polycarbonate sheets are either transparent or translucent – this means that you can see through them to varying degrees. This also means that you will see any leaves, bird droppings, dirt etc on the top of the sheet. One of the reasons that a 5 degree fall is recommended is for self-cleaning of the sheets.
      2. Water run off – a flat roof is much more likely to leak, hard to flash and hard to control where the water may run off – i.e. against the walls of the house!
      3. Water pooling – if the water is not running off it can pool on top of the sheet. While polycarbonate is very strong it may sag under the weight of the water. This probably won’t be too much of a consideration for you as you have lots of purlins close together – which would most likely stop possible sagging effect.
      4. You may void parts of your manufacturers warranty.

      If you did decide to go ahead you would screw in the usual way through the crest using a TEK head polycarbonate screw (such as Clearfix or Oneshot).

      I hope this helps
      Polycarbonate Roofing.

  24. Reply
    June 5, 2017 at 12:16 pm
    Caroline

    Hi,
    Have just had a new polycarbonate ‘roma’ clear roof installed (about 3weeks ago), very happy with the result, but, I can see patches of residue from the removed stickers, please could you advise how I can get the sticky stuff off without marking or damaging the ploycarbonate. Worried if I leave it too long it may harden therefore making it harder to remove.
    Thanks.

    • Reply
      June 19, 2017 at 3:49 pm
      Polycarbonate Roofing

      Hi Caroline

      You have to be a little careful not to damage the UV coating on the sheet. Therefore NO abrasives or chemicals. Some warm water with a mild soap and a little ‘gentle’ persistence may be the best answer. Most manufactures have stickers that are designed to not leave any residue behind… Try to get to it sooner rather than later.

      Best of Luck Polycarbonate Roofing.

  25. Reply
    June 10, 2017 at 8:57 am
    Reijo

    Condensation under polycarbonate.Rafters attached to fascia with painted timber battens.fall away from house roof.Roofing starts above existing spouting with 100mm over hang and falls away from house at minimum fall to the new spouting.I am a builder an have never had a problem with condensation under polycarbonate (Tas)

    • Reply
      June 19, 2017 at 3:53 pm
      Polycarbonate Roofing

      Hi Reijo

      Condensation can occur on all types of roofing, Polycarbonate is no different. It is usually caused by a temperature differential on either side of the sheet. It is pretty hard to control but increased air flow usually helps.

      Thanks Polycarbonate Roofing

  26. Reply
    June 12, 2017 at 8:03 pm
    Js

    How to connect the top of the greca roof to the gutter of my house? The gutter is at a lower position

    • Reply
      June 19, 2017 at 3:56 pm
      Polycarbonate Roofing

      Hi Js

      There are a few ways to do this, depending on where the roofing actually finishes.

      A back channel can be used to go either under the gutter or in some cases but into it. Otherwise a custom flashing going from the top of the roofing and turning into the gutter may be needed.

      Kind regards
      Polycarbonate Roofing.

  27. Reply
    June 19, 2017 at 11:03 am
    Bill

    Is there any professional installation service to be recommended? The proceed of installation is a little bit complicated.

    • Reply
      June 19, 2017 at 3:57 pm
      Polycarbonate Roofing

      Hi Bill

      We are a supply only company. For most products a handyman should be able to help you regarding installation.

      Kind regards
      Polycarbonate Roofing.

  28. Reply
    June 19, 2017 at 3:34 pm
    Damien

    I currently have a roof area of 17m x 8m over my pool (skillion roof) that is covered with colorbond sheeting. I would like to get some light in and was thinking of replacing some colorbond sheets with clear or tinted polycarbonate. What is the best way to fix a polycarbonate when matching it to existing colorbond shets (using one shot screws)?

    • Reply
      June 19, 2017 at 4:01 pm
      Polycarbonate Roofing

      Hi Damien

      Once you have matched up the profile of your colorbond to the Polycarbonate its pretty easy. One Shots are good for going through the polycarbonate only sections, but where the sheets lap with metal you will need a different screw as the cutter on this type of screw will get in the way. You will need to pre-drill a expansion hole in the polycarbonate and then use a standard roofing screw with a polycarbonate compatible washer to fix.

      We trust this helps

      Team Polycarbonate Roofing.

  29. Reply
    July 8, 2017 at 10:57 am
    Graham

    I intend using corrugated polycarbonate on the south facing wall of a shelter.
    Due to orientation and location, the south wall it, is likely to have sunshine on winter mornings on the INSIDE of the wall, and sunshine on the OUTSIDE of the wall on late afternoons in summer. Which side should face out to avoid UV damage?

    • Reply
      July 9, 2017 at 11:42 am
      Polycarbonate Roofing

      Hi Graham

      Thanks for the question. Using a corrugated sheet in this way is not advisable as it is only UV treated on one side – the sheets are all marked on one side with “this side up”. You might want to consider a twinwall like SUNLITE as it us UV treated on both sides and is probably better suited to this job.

      If you wanted to proceed with the corrugated sheeting you would need to decide which surface would get less UV and orientate the sheets accordingly.

      Thanks – Team Polycarbonate

  30. Reply
    July 16, 2017 at 5:25 pm
    Dieter

    Can I Install Polycarbonate Roofing Sheets straight onto the Rafter without purlins? (Rafter about 600 distance)

    • Reply
      July 17, 2017 at 5:26 pm
      Polycarbonate Roofing

      Hi Deiter

      Thanks for the question. Some polycarbonate systems can be installed onto purlins. For ‘profiled’ sheets it is NOT possible – you require purlins. For Twinwall or multiwall sheets – it is possible, though some are better suited than others. This will depend on the exact distance between the rafters.

      Sunlite can be cut down to suit any size.
      http://polycarbonate.com.au/suntuf-sunlite-twin-wall-polycarbonate/

      Sunpal has sheets with fixed widths and rafter centers of 602 mm.
      http://polycarbonate.com.au/sunpal-multiwall-polycarbonate/

      Hope this helps
      Team Polycarb

  31. Reply
    July 19, 2017 at 9:30 pm
    Deniz Ibrahim

    Hi,

    I have recently installed the roof sheeting to a pergola. I have noticed local water build up at the end span next to the gutter. The end span sheet is sagging down and then past the last rafter (extending into the gutter) the sheeting is lipping back up. I have checked the screws and they are generally level. Would the sag in the sheet be due to overtightened screws or the end span in the sheet being to long?

    Deniz

    • Reply
      July 20, 2017 at 8:23 am
      Polycarbonate Roofing

      Hi Deniz

      Thanks for the question. There are a few possibilities here…

      1. As suggested your end spans are to large. For standard profile you will find a list of the maximum end spans listed in the second table on the linked page
      LINK HERE – table for end spans

      2. As also suggested it may also be a screw problem – there are two possible causes here:
      a. Screw over tightening. The washer should contact the sheet without causing the sheet profile to deform, in other words it should sit pretty naturally. It seems that you have check this!
      b. Not predrilling an expansion hole (or not using screws that have cutter to do this automatically) – this can also cause the sheet to buckle (normally during the hottest part of the day).

      My guess without know your profile or end spans it that its most likely to be end spans… feel free to come back with this info.

      Hope that this helps.
      Team polycarbonate.

  32. Reply
    July 22, 2017 at 4:58 pm
    Bev Murray

    Hi
    We have installed Greca roofing over a pergola. All good except the ridge capping (Greca profile) doesn’t sit flush once screwed onto the sheets. If we take it off & put on a non profile ridge cap, what is the overhang required from the ridge cap to the sheet? Does the ridge cap come only one width? If the ridge cap doesn’t provide enough coverage is the only option to re roof with more overhang at the top?
    Thanks
    Bev

    • Reply
      July 26, 2017 at 2:28 pm
      Polycarbonate Roofing

      Hi Bev
      My first thought is they have screwed down too tight which is distorting the ridge cap. So might pay to check and maybe ease off a little?
      Failing that the non-profiled ridge cap does only come in one size which is 130mm each side.
      If you are worried about the cover then you could get a colourbond ridge capping pressed up to your requirements (supplied by others) and use the foam infills to seal the profile (as you could use also with the ‘flat’ polycarbonate ridge capping. Colourbond will probably work out cheaper than the polycarbonate flashings.
      I cant attach anything through this system so I will email you some drawing separately.
      Regards Judy
      Polycarbonate Roofing

  33. Reply
    July 31, 2017 at 7:39 pm
    Karyn

    What type of flashing or capping do I use if running the Suntuff sheeting along a chamfer wall longways

    • Reply
      August 1, 2017 at 10:42 am
      Polycarbonate Roofing

      Hi Karyn

      If I understand correctly you are looking for a flashing that will be running down the length/side of the sheet against the house?
      Your best option would be to get a colourbond apron flashing. You can get these pressed up at a local sheet metal place. You can give them
      the measurements and they can make to suit. Make the width of the flashing far enough to cover over at least one
      corrugation on the sheet to waterproof. You can then seal the metal flashing to the wall.

      Thanks Judy

  34. Reply
    August 4, 2017 at 11:45 pm
    Robert

    Can I use brute flashing tape on polycarbonate to form a water tight seal or will this damage the polycarbonate?
    Thanks
    Rob

    • Reply
      August 7, 2017 at 3:00 pm
      Polycarbonate Roofing

      Hi Robert

      Thanks for the question. Did you mean Byute Flash…? We recommend a Butyl Rubber for sealing in some circumstances. I can see that this product is mostly made from this, however I am not sure regarding some of the other ingredients (taken from the safety data sheet). Maybe a standard flashing with some infills – to be safe?

      Regards
      Team PC

  35. Reply
    August 5, 2017 at 3:01 pm
    Roofing 2000

    useful tips…

    thanks you so much Polycarbonate Roofing Team

  36. Reply
    August 7, 2017 at 9:31 am
    Sam

    Hi
    I have been asked to replace all screws to an entire roof. How ever the screws supplied are a oneshot polycarbonate fixing and the existing roof sheets are tin!
    Is this still within australian standards??
    I think the customer is trying to achieve a more durable rubber but im curious because these screws dont have the second thread to help pull the sheet to the battern

    • Reply
      August 7, 2017 at 3:02 pm
      Polycarbonate Roofing

      Hi Sam

      My main concern here would be the cutter on the OneShot screws – this is deisgned to cut the polycarbonate and isnt really suitable for metal/tin sheets. I suspect you will have no luck getting them in.

      I am not sure if it would comply with AS.

      Team PC

  37. Reply
    August 29, 2017 at 9:59 am
    Adam

    Hi,
    Just curious if there any any issues with overlapping corrugated sheeting by more than recommended? Ie. 2-3 full corrugated overlaps? Issues with holding water or mould, etc?

    Cheers

    • Reply
      August 29, 2017 at 10:51 am
      Polycarbonate Roofing

      Hi Adam

      Thanks for the email. The simple answer is yes. It will be dependent on fall, but dirt can build up in any lap. Sometime people will do this for ‘extra’ waterproofing on low fall situations, there is no harm – but it can look unsightly.

      Team polycarbonate.

    • Reply
      July 1, 2019 at 10:43 am
      Polycarbonate Roofing

      Hi Adam

      The short answer is yes, you may get more visible dust/dirt between sheets. Maybe a butyl rubber could help (this is also visible, but generally better looking). The greater the fall the less the risk, are you using extra laps due to low fall?

      Thanks Team PC

  38. Reply
    August 29, 2017 at 10:15 pm
    Neill Wiseman

    I have a polycarb sheet lifting on the left edge as the screw no longer holds it. The sheet is 2/3 from front edge. Is there a way to re-fasten from the inside. I cannot reach the edge in question and i dont belive the structure will take my weight.

    • Reply
      August 31, 2017 at 9:45 am
      Polycarbonate Roofing

      Hi Neill

      Sorry, but if I am understanding you correctly, I don’t think what you are suggesting is possible. While it may be possible to get a screw in from below, I don’t believe that it would hole for long. Any options for a stitching screw setup with a ‘grommet’ (see below image) on the end of the screw would require a hand on the top to secure… so would still require you to be on the roof.

      Screw with Grommet

      I hope this helps?

      Regards
      Team Polycarb

  39. Reply
    September 11, 2017 at 4:31 pm
    Ross Litchfield

    Hi just after a little bit more guidance on the back channel, foam and roofing sheet combination installation, am I correct in saying, I secure the channel to the wall, install the foam into the channel, then butt the roof sheeting up to the foam in the channel with a little pressure against the foam then screw sheets in place. Any other advice?

    • Reply
      September 19, 2017 at 8:01 am
      Polycarbonate Roofing

      Hi Ross, yes you have the idea. Some people will just pin the back channel to the wall using the sheet and then silicon the back channel. you may need another set of hands to help with this method though.

      Hope this helps
      Team PC

  40. Reply
    September 11, 2017 at 5:04 pm
    Michelle

    We have built a wooden frame approx cover 34m2. We have 1 beam attached to a wall and 3 more cross beams running in the direction we want to put the roof sheets (width of area…. 5.5m). Our question however, how many beams do we need for support on the longer side of the structure… i.e approx 6.2m .

    Area to cover: 34m2 (5.5m long x 6.2m wide) i know we will need about 10 sheets of 5.5m. Will placing beams 1m apart in the width suffice?

    • Reply
      September 19, 2017 at 8:13 am
      Polycarbonate Roofing

      Hi Michelle

      Thanks for your question.

      The answer will depend on what product you are using. I will assume that because you have comments on this particular post that you are referring to a profiled sheet i.e. corrugated, greca or trimdek profile.

      If I understand you correctly, you will have rafters 5.5 m long (this is the direction of the fall on the roof) and your purlins will need to be 6.2 m long (these run perpendicular to the length of the sheeting)… see below for clarification. So you need to know what spans the purlins are placed apart

      Roof structure

      This information can be found here. Look at the second blue table – you need to look at the “Maximum Mid Spans” and “Maximum End Spans” – these will change pending the profile.

      Hope this helps

      Team PC

    • Reply
      October 8, 2020 at 6:18 pm
      Alan Slater

      Hi. At the overlap of each sheet, do you place an extra screw in this edge or can you skip it and keep to your screw placement in every 3 or 2 corrugations?

      • Reply
        October 8, 2020 at 7:04 pm
        Polycarbonate Roofing

        Hi Michelle
        The overlap must always be screwed down, so no you cannot skip it. This will disrupt the 2-3 pattern so you must add an extra screw if required.
        Team PCR

  41. Reply
    September 18, 2017 at 7:28 pm
    Josie Wilson

    Hi,
    We recently installed corrugated polycarbonate roofing on our pergola but used too few screws. I’m wondering if we can get up on the roof to add more screws. If we lie across the rafters so the weight is distributed would that be ok? Ie. how much weight can they take?
    Many thanks!

    • Reply
      September 19, 2017 at 8:16 am
      Polycarbonate Roofing

      Hi Josie

      This can be done, the use of crawl boards is recommended. This is a plank that spans across a number of supports to distribute your weight. Be sure not to scratch the plank over the sheeting.

      Hope this helps

      Team PC

  42. Reply
    October 2, 2017 at 7:17 pm
    Peter k

    Hi,

    I recently used your one shot steel screws on a metal/tin roof on the advice of a Bunnings worker. After reading the packaging etc I see these screws are for polycarbonate sheeting into steel. The screws went in fine and straight and the washers are sitting tight. What are your thoughts on this long term?

    Thanks in advance.

    • Reply
      October 5, 2017 at 12:06 pm
      Polycarbonate Roofing

      Hi Peter

      Thanks for the questions. We are not confident on our answer to this one. In theory the screw should be ok… we were all a bit surprised that you managed to get the screws in! The problem would be that to change them you would need to consider how to manage the larger hole that the screw would have cut in the metal sheet. Maybe not worth worrying about?

      Sorry we can be of more help with this one.

      Team PC

  43. Reply
    October 25, 2017 at 3:50 pm
    Peter

    Hi, just a question, I am installing Suntuf over a pool pump and filter setup. and being only a small structure, what is the maximum length that can be installed without any support under the polycarbonate? It would only be a couple sheets wide. Screwed front and back with a slight fall?
    What is the best colour for best UV block out as there will be no sides/ walls, only a roof over the equipement?

    • Reply
      October 26, 2017 at 9:19 am
      Polycarbonate Roofing

      Hi Peter
      Thanks for your enquiry. Maximum span would depend on the profile of the sheet you would be using. Do you have a preference? What would the length of the span be?
      All the polycarbonate provides 99.9 UV protection regardless of colour. Different colours then reduce heat and light so probably just pick a colour that is going to match whatever you have around.

      Regards Judy

  44. Reply
    October 27, 2017 at 5:02 am
    Christina

    What should the distance be from chimney pipe to suntuf

    • Reply
      October 27, 2017 at 5:08 am
      Christina

      Im puttung suntuf over my deck.. I have a wood stove, how far from stove should i stop the suntuf.

      • Reply
        October 27, 2017 at 7:56 am
        Polycarbonate Roofing

        Hi Christina
        Just to clarify is the flue of the wood stove going through the Suntuf sheet?
        Thanks Judy

    • Reply
      December 5, 2017 at 8:03 am
      Polycarbonate Roofing

      Hi Christina

      Suntuf has a long term service temperature of 100 degree C. It would depend on the flue system – but you would need to ensure that the temp stays below this. There maybe laws around this also you need to consider?

      Thanks Team PC

  45. Reply
    December 11, 2017 at 3:10 am
    Dwane

    How does polycarbonate roofing hold up in the desert sun of AZ? Maintanence? Years of service?

    • Reply
      January 24, 2018 at 1:15 pm
      Polycarbonate Roofing

      Hi Dwane

      We cover Suntuf products in Australia – you question is probably best answered from someone in the US – they will be able to guide you on local warranties etc.

      Thanks Team PC Aus!

  46. Reply
    December 22, 2017 at 12:43 pm
    Rose Kizinska

    Hi there,
    I have just installed 5 sheets on the pergola roof and 3 of them have buckled at the overlap towards the top of the panel, closest to house roof. The screws are not overtight as they are the self-cutting type. Now I do’t know if there will be leakage if it rains.
    I’m not sure how it happened but it looks terrible! Please advise.
    Thanks.
    Rose

    • Reply
      January 19, 2018 at 11:09 am
      Polycarbonate Roofing

      Hi Rose

      Thanks for the message. it is hard to suggest things without seeing the sheeting. The main areas of concern would normally be over tightening the screws (this can still be done with screws with cutters). basically you should be looking got good contact with the washer without deforming the profile of the sheet. Are both sheets clear of the cutter on the screw – maybe they have been caught? The other area may be making sure the sheets have been laid square – this may be why it is out on the one end more?

      Hopefully this may help. Good luck!
      Team Polycarbonate

  47. Reply
    December 30, 2017 at 4:55 am
    Alan

    We have a pyramid pergola with thatch covering. We are thinking of ditching the thatch and replacing it with your product. But we’re not very clear as to how we would “cap” the structure at its apex. Any suggestions?

    • Reply
      January 19, 2018 at 11:12 am
      Polycarbonate Roofing

      Hi Alan

      This type of capping is usually referred to as a ridge cap olong each of the sides. The ‘cap’ section would probably be best to see a local metal fabricator – the would bee able to bend you something to suit.

      Team polycarbonate

    • Reply
      July 1, 2019 at 10:45 am
      Polycarbonate Roofing

      Hi Alan

      Thanks for the question. For this type of ‘flashing’ you are best to speak with a local metal fabricator to have something folded in metal to fit. We can also supply foam infill for most products if required.

      Team PC

  48. Reply
    January 1, 2018 at 6:32 pm
    Brendan

    hi,
    I am looking for a guide to installing a suntuf ridge cap?

    • Reply
      January 19, 2018 at 11:15 am
      Polycarbonate Roofing

      Hi Brendan

      I have not seen any specific guide for this. Generally it is treated that same way as the sheet. Screw through the ridge cap (then the sheet) with your screws. The below link covers a few basics for this…

      http://polycarbonate.com.au/suntuf-installation-guide-tips/

      Thanks Team PC

  49. Reply
    February 5, 2018 at 7:23 pm
    Laurie John

    Hello,
    I’m building a flat roof verandah attached to the back of my house.
    Fall is 5 degrees and I’m using corrugated clear poly.
    The end wall of the house is flat continuing up as an end gable.
    The gable is fibre cement sheet, the lower part of the wall is colourbond corrugated steel sheet which will be under the verandah. There is a 600mm eaves at this end of the house .
    The main support beam attached to the house id 140mm x 35 mm Treated Pine.
    What do your recommend for sealing the poly sheets at the house end,
    Metal Back Channel 40mmx 20mm with foam infill….
    or
    Apron Flashing ( Corrugated ) with foam infill.
    Verandah length is 6000mm ( 6 Metres )
    Obviously Metal Back Channel will be the most cost effective .
    The verandah is on the opposite side of the house to the normal prevailing weather side.
    Thanks,

    • Reply
      February 6, 2018 at 10:27 am
      Polycarbonate Roofing

      Hi Laurie

      Thanks for the questions. You are correct the back channel will be cheaper option. The PC apron probably makes life a little easier as it will be flexible enough to account for the pitch. you will have a small gap behind the back channel due to the pitch – this can be siliconed for water proofing. If you get the profiled apron you won’t require the infills. There is no wrong way from what you have suggested – clearance sometimes dictates which way you would need to go.

      Thanks Team PC

  50. Reply
    February 8, 2018 at 11:17 pm
    toni

    Hi Laurie

    Any idea roughly how many screws needed for 16 sheets of suntuf -width 860mm and 2.6 length ?

    • Reply
      March 20, 2018 at 11:15 am
      Polycarbonate Roofing

      Hi Toni

      Would would suggest around 250 screws for this area – this equated to approx 8/sqm.

      Thanks team PC

  51. Reply
    April 25, 2018 at 4:27 pm
    Bob

    Hi, we built a timber-framed, polycarbonate sheeted roof over our deck about 8 years ago. In heavy rain water drips from the two hips. The drips appear to be coming from screw locations. The screws are those with the cutter and rubber washer. On inspection the rubber washers at most screws are severely cracked, and sometimes missing. How long are these washers expected to last? I have tried to remove a screw to replace, but with the cutter in place it is difficult to remove the screw. What now?

    • Reply
      May 24, 2018 at 10:21 am
      Polycarbonate Roofing

      Hi Bob

      Thanks for the message. These washers will of course deteriorate, but I have never heard of them being problematic that early. AS you suggest the best course of action would be to replace the screws, some care would need to be taken.

      Unfortunately there is no easier fix that I am aware of.

      Thanks team PC

  52. Reply
    July 9, 2018 at 3:10 am
    Jamie

    I am going to use polycarbonate roofing panels underneath my new deck to keep the area underneath dry. I do not want to use perlins, as leaves will become trapped, so I am planning to rip some pressure-treated pine with constant slope and attach along the length of the joists, then attach the panels to that. Sound reasonable? Also, joists are on 16″ centers, and the 12′ panels that I need are 26″ wide. Suggestions for how to handle the overlap?

    • Reply
      July 26, 2018 at 11:36 am
      Polycarbonate Roofing

      Hi Jamie

      It really depends on what sheet you are looking at using. A profiled sheet (e.g. corrugated or greca) wont be suitable – if I am understanding your email correctly. These types of sheets require the support of purlins, otherwise they will sag.

      If you are look at a twinwall like a sunlite, this would be possible. However you would need to rip the sheets down so that they join on your ‘rafter’ or timber.

      I hope this helps.

      Team PC

  53. Reply
    August 8, 2018 at 1:21 pm
    Peter

    Hi, I am in the process of designing an outdoor area in Melbourne, size being approx 8m x 8m using PC sheet (corrugated or greca) for roofing. Given the temperature range where we can have +/- 20 degrees during a 24hr period, is it ok to use OneShot screws on a sheet of 8mtrs in length or do you advise larger fixing holes. Also can I assume that if a PC sheet at 8m in length can expand by approx. 20mm @ 0-40 degrees, it will then expand by half that for +/- 20, as we would never experience a temperature variance of 0-40 in Melbourne, the norm being +/-10-15 degrees. Thanks.

    • Reply
      August 14, 2018 at 8:51 am
      Polycarbonate Roofing

      Hi Peter

      Thanks for the great question.
      When installing longer sheets (over about 7m) drilling an over sized hole is good practice. The OneShot screws are designed to cut a 10 mm hole. You would need to drill the sheets with a 12 mm bit, then use a ‘normal’ screw (without cutter) with a Polycarbonate compatible washer, to cover the hole. I trust this answers your question.

      Thanks Team PC

  54. Reply
    August 13, 2018 at 5:18 pm
    Geoff Baxter

    I have recently installed Laserlite 3000 Grecia pattern to our patio. However I unwittingly selected too light a shade colour & consequently the light penetration can be too great particularly in bright sun light conditions. Is there a paint product available that can reduce the intensity of the UV rays and still allow reasonable light penetration.

    • Reply
      August 14, 2018 at 8:54 am
      Polycarbonate Roofing

      Hi Geoff
      Sorry to hear about your problem… There is nothing that we are aware of that will do this. Generally speaking painting poly sheets is not advised. Maybe you could use some shade cloth to help?

      Let us know if you need anything else.
      Team PC

  55. Reply
    August 29, 2018 at 12:55 pm
    ken

    does the polycarbonate has a tendency in leaking?

    • Reply
      August 31, 2018 at 11:20 am
      Polycarbonate Roofing

      Hi Ken

      No more or less than any other style of roofing. It will largely depend on structure and installation. Low pitched roofs are always more prone to leaks (no matter the roofing material). When installed correctly, all of these systems should be leak free.

      Trust this helps
      Team PC

  56. Reply
    September 15, 2018 at 8:10 am
    Ryan

    I am installing the polycarbonate suntuf panels to the roof of my greenhouse. I am using the closure foam on the top, bottom and sides. The supporting cross sections going through the middle, Can I directly screw them to the wood framing or do I need the foam between the panels and wood? Thank you for your time

    • Reply
      September 17, 2018 at 8:49 am
      Polycarbonate Roofing

      Hi Ryan

      Thanks for the question. I believe from your email you are referring to infills. These are foam pieces shaped to suit the profile of the sheet. They are not required. A cheaper option if you did want to do something is purlin tape. This is a flat foam tape (sticky on one side). It is used to reduce creaking and cracking of the sheet as it expands and contracts. This is particularly useful if you have painted timber purlins. But again it is not required.

      We hope this helps.
      Team PC

  57. Reply
    September 19, 2018 at 4:05 pm
    Bruce

    I’m having problems with mould. Is there any method of preventing this by treating new sheets or removing the mould once it has grown on the sheets?

    • Reply
      September 24, 2018 at 1:20 pm
      Polycarbonate Roofing

      Hi Bruce

      Thanks for the question. There is no pre-treatment that I am aware of that will help to prevent the growth of mould.

      Generally, the simplest cleaning method for polycarbonates is a mild detergent with a cotton cloth or soft bristled broom (rising thoroughly afterwards). I have also attached the chemical resistance document which may guide you if your require something to kill mould. See here.

      I suspect that you are past the design stage, but a steeper fall is also useful here. Trimming any trees etc if they are shading the roof area, allowing more sunlight onto the sheets can also assist. Regular cleaning may also prevent buildup.

      We hope this helps

      Team PC

  58. Reply
    November 3, 2018 at 2:31 pm
    Gabriel Hernandez

    Hi
    I’m am installing a suntuf clear corrugated roof including flashing.

    In regards to the flashing and attaching it to a weathertex wall am I right in assuming I have to cut a line along the entire span of flashing to put that little lip of the flashing in before I seal it with sillaflex.

    Do I then drill the flashing into the wall and then on top of the sheets into the Perkins?

    Sorry for the questions there isn’t much out there on flashing installation.

    Kind regards
    Gabes

    • Reply
      February 12, 2019 at 5:05 pm
      Polycarbonate Roofing

      Hi Gabriel

      We can’t comment on the weathertex sorry! Certainly the flashing is secured to (on top) of the sheet and into the wall. If you are using any silicones be sure to use a polycarbonate friendly on (neutral cure). Were you using metal or poly flashing… metal will expand and contract less. If using poly shorter strips help.

      Team PC

  59. Reply
    December 7, 2018 at 4:45 pm
    Colin

    What sort on material (if any ) can be placed as close as possible to the underside of clear suntuf sheeting during summer season?
    Or is this something which would reflect onto underside and create probs?

    I was thinking of something thin,light in colour,low in thermal mass like fibre cement.
    Maybe even with some sort of thin insulation medium if it is do-able.
    Shade sails under the sheets is partially helpful but I think it’s an ‘after the horse has bolted’ bandaid

    • Reply
      February 12, 2019 at 4:59 pm
      Polycarbonate Roofing

      Hi Colin

      Thanks for the question. There should be too many worries with solid products (such as fibre cement) or shade cloth etc… the only consideration is reflected UV. Depending on your sheets they may be UV treated on 1 side (facing up) which means if they are exposed to reflected UV they may deteriorate more quickly.

      We trust this helps

      Team PC

  60. Reply
    January 5, 2019 at 3:20 pm
    Greg

    What is the best way to attach the sheeting at the house end of the sheet (within the back channel) as where I am installing it, it is very windy so I want the added stability. Can you use a long pot rivet ?

    • Reply
      January 10, 2019 at 2:18 pm
      Polycarbonate Roofing

      Hi Greg

      I am not 100% sure what you are meaning here. Maybe adding additional screws to the last purlin is the best option? Otherwise usually the sheeting would simply sit into the back channel (into foam) which could be secured to the wall.

      Hope this helps.
      Team PC

      • Reply
        January 12, 2019 at 12:21 pm
        Greg

        Thanks for your reply, the problem I have got is that the back channel is larger than the sheeting, I got back channel for the ribbed format and the sheeting is the corrugated one and I cant exchange any of it so I was thinking of attaching the sheets some how into the back channel (against foam) to make it more secure, as the area I am doing is approx. 25 mtrs long.
        Thanks
        Greg

        • Reply
          January 21, 2019 at 2:15 pm
          Polycarbonate Roofing

          Hi Greg

          Ok, a little tricky! Riveting would probably not be great over time due to the forces of expansion and contraction that it will experience.

          Maybe another strip of foam to sit above the corrugated sheet – between the sheet and the top of the channel? You can get infills that would work ok – but i think it may still be loose in the back channel depending on the actual dimension!

          Hope this is of some help.

          Team PC

  61. Reply
    February 7, 2019 at 2:01 pm
    Steve

    I’m installing a new roof of 6/11 m lengths of Spandek with a strip of polycarbonate half way across. The poly is in 2/6m lengths so I need to over the 2 sheets 1/2 way along with an approx 1 m overlap (saves cutting the poly to shorter lengths. How should I seal the overlap to prevent water ingress. I’ve seen some sort of tape in my travels through the interweb, plus a mention of silicone, or a Sikaflex type non-silicone. Which is best?

    • Reply
      February 7, 2019 at 3:12 pm
      Polycarbonate Roofing

      Hi Steve

      Thanks for the question. Silicone or Sika is NOT a good idea. Polycarbonate will expand and contract and these can damage the sheets. We recommend the use of a sealing tape (which we can supply) either side of the screw line.

      In regard to the sheet lengths, we would normally recommend trimming the excess from the sheets, this will always give the cleanest look. We can always trim these to length for you if this makes life easier.

      I have added a link to the full installation guide for your reference.

      INSTALLATION GUIDE

      Let us know if we can help with anything else.

      Thanks
      Team Polycarb

  62. Reply
    March 12, 2019 at 9:00 am
    Paul

    Hi
    I have a corrugated suntuf roof on a pergola and need to cut a 150 mm round hole into the roofing for a flu from a range hood exhaust fan. What is the best way to do this?

    • Reply
      March 12, 2019 at 10:33 am
      Polycarbonate Roofing

      Hi Paul

      Thanks for the question.

      For a cut like this, you best bet would be a good pair of scissors! Start the hole with a drill is probably easiest. You will find it quite easy to cut with scissors.

      We trust this helps
      Team PC

  63. Reply
    March 17, 2019 at 8:07 am
    Shah

    Hello
    We recently had a bad hailstorm in Sydney which has put some holes in my existing roofing. I want to replace it with a Suntuf clear polyC panels. Apart from removing old sheets and replacing with new, is there anything I need to consider

    • Reply
      March 19, 2019 at 8:35 am
      Polycarbonate Roofing

      Hi Shah

      Thanks for the question.

      Mostly its pretty straight forward… you may also want to consider new screws, depending on the age the washer may have also become brittle. Depending on the what the flashing is made from, you may be able to reuse it.

      Other components that may be useful are purlin tape and infill (if required).

      Remember to be careful when removing old sheet – they can be brittle. Do not stand on them.

      Team PC

  64. Reply
    March 25, 2019 at 10:49 am
    Catherine

    Can you have gyprock installed under a polycarbonate roof or are their building standards that dont allow this?

    • Reply
      April 3, 2019 at 12:28 pm
      Polycarbonate Roofing

      Hi Catherine

      This is something you would need to confirm with your local building authority.

      Team
      PCR

  65. Reply
    April 9, 2019 at 12:08 am
    Marshall

    Hi There,

    Is there such thing as lipped roof panels? normally i would use glass for roof panels and add a 70mm lip to the outer pane. is this possible for Polycarbonate roof panels?

    thanks

    • Reply
      April 11, 2019 at 9:22 am
      Polycarbonate Roofing

      Hi Marshall

      Thanks for the question… there are some panels that have ‘lips’, though we are not sure about what you mean.

      You are probably best to seek a supplier in the UK (we are in Australia), as it seems like you are in the UK?

      Team PC

  66. Reply
    April 23, 2019 at 1:13 pm
    Sue Watson

    Hi, I had a 3.2 x 3 m steel pergola installed in my courtyard by a builder in January, with polycarbonate roofing. It is constantly making a cracking noise when it heats up every day for nearly 2 or more hours, no matter if the sun is out or not, which is very annoying. Can you advise if this can be fixed by the builder, as its still under warranty. What should I tell the builder to do to fix the problem. Hope you can help with this enquiry. Many thanks

    • Reply
      May 8, 2019 at 10:07 am
      Polycarbonate Roofing

      Hi Sue

      There are 3 potential causes/solutions that we may suggest.

      1. Noise tape – used on purlins to reduce noise as the sheets expand and contract – this is usually more important on painted timber.
      2. Screws over tight
      3. No expansion hole around the screw. (not using self cutting screws or failure to pre-drill holes for screw)

      Polycarbonate will expand and contract which can lead to noise. If you think it is excessive you may want to check the above.

      Trust this assists in helping to resolve the problem.

      Team PC

  67. Reply
    April 26, 2019 at 11:35 am
    Mark

    I need to fix my hail damaged skylights that are made with poly-carbonate Greca profile that flush mounted onto metal roof with matching profile .
    My problem that all Greca profile poly-carbonate sheets I find on-line have 76mm between the ridges, where my old roof and skylights are approximately 90mm between the ridges.
    Please advise where to find the old Greca profile poly-carbonate sheets or if they don’t make it anymore what’s the alternative

    • Reply
      May 8, 2019 at 10:11 am
      Polycarbonate Roofing

      Hi Mark

      I would suggest that the product you have is not Greca, but could be Spandek (metal), with the poly equivalent being SPANTUF. Please check the below profile drawing to ensure that this will match.

      spantuf profile image

      Trust that this helps?

      Team PC

  68. Reply
    May 6, 2019 at 8:32 am
    Francis Chen

    Hi, I am having a new pergola roof area 8.12Mx 3.6M to attach my South side backyard brick wall in Sunnybank Qld and bought 11 sheets SUNTUF STD GRECA CLEAR 3.6M. Is 11 sheets is right enough for 8.12M ? I have prepared 6 Dulux Weathershield painted purlins for 5 spans intervals , is it wasteful and too many holes on carb. roof to have 4 spans enough ?
    I read your installation guides and conclude that ; I have to bend my upper body forwards about 760mm the farthest to drill the screws in mid spans ??, it looks a bit difficult to keep the drill machine perpendicular to purlins although I am 175 tall.
    My friend told me to coil the sheet from side I am afraid it can’t be that .
    Why don’t you have a detail illustrated pictures for this?
    Thanks

    • Reply
      May 8, 2019 at 9:45 am
      Polycarbonate Roofing

      Hi Francis

      Thanks for the questions.

      11 sheets is correct for the structure width of 8.12m, each sheet has a cover of 760 mm once you account for the overlap.

      I am not sure 100% what your spans are but the mid spans on Greca profile can be 1200 mm with end spans 900 mm. If I understand you correctly your spans will be approx 900 mm – which is fine.

      In most occasions (with the use of a ladder) installation is done by leaning over.

      Let us know if we can assist further.

      Team PC

  69. Reply
    May 11, 2019 at 5:57 pm
    Ryley

    I am installing a polycarb apron flashing on a pergola roof butts up against the house and does not have enough pitch. The pergola roof is metal. Will i need to predrill expansion holes in the apron flashing or will expansion not be an issue with such a small piece of polycarbonate? most of the polycarb will see the sun.

    • Reply
      May 23, 2019 at 10:34 am
      Polycarbonate Roofing

      Hi Ryley

      You are correct, as the pieces of flashing are generally smaller they will have less expansion. We do however recommend that you still use an expansion hole to be safe.

      Trust this helps
      Team PC.

  70. Reply
    May 20, 2019 at 6:55 am
    Jason

    Hi I have installed 1piece of suntuf corregated polycarbonate tinted sheet in the roof to allow light into our bedroom because it is dark. There is 1 batten or Purling not sure what it’s called but the piece of timber the polycarbonate is screwed to that is visible and condensation drips at the batten. How do I stop this ? Could I use the corrugated foam infill ?
    Thanks in advance.

    • Reply
      May 23, 2019 at 10:32 am
      Polycarbonate Roofing

      Hi Jason

      Thanks for the message. There is no easy solution to this – it is caused by a difference in temp inside and out. I don’t believe that a foam infill will stop this.

      Maybe a piece of twinwall a little below the corrugated sheet (still lets light through) may help to reduce the chances of condensation forming on the sheet?

      Trust this helps
      Team PC

  71. Reply
    June 27, 2019 at 10:00 pm
    Harry Couchman

    I am planning to put a roof over an ‘L’ shaped verandah using Sunlite 10mm twin wall sheeting . One leg of the ‘L’ will be 4000mm wide and the other leg 1800mm. Both will be approximately 6000mm in length. The sheets will be fastened to Alyspan 100 x 50 steel patio rafters on 1000mm centres. The fall will be 5 degrees, perhaps a little better. As a hip will be created, can you tell me what is the best way to seal this?

    • Reply
      July 1, 2019 at 12:58 pm
      Polycarbonate Roofing

      Hi Harry

      Thanks for the question. Essentially, you will treat the raked edge the same way as the top side edge of the sheets. There are a few option here pending your circumstance. Then get a ridge cap folded to suit and screw this to the h bars at each junction.

      Trust this answers your question. Give us a call if you need anything else.
      Team PC

  72. Reply
    June 29, 2019 at 2:50 pm
    Edwin

    I have a pergola with laserlite sheets along the back of the house (10m length x 4m width) it is about 10 years old. the sheets are fine but since last year if found they the end towards the house has stared leaking from the gap. I assume the silicone at that end has come off sue to expansion and contraction – how can i fix this is it from under the pergola or on the laserlite sheets and can i stand on a timber sheet on the laserlite sheets – Thanks in advance

    • Reply
      July 1, 2019 at 12:52 pm
      Polycarbonate Roofing

      Hi Edwin

      Thanks for the question. There is a good chance that you are correct regarding expansion and contraction. Ideally, silicon is not used in this method – a back channel or apron flashing is generally the norm. Fixing it is probably a hard task. Given its age it is possible that you may crack the sheets when using a crawl board. Given this the only solution may be trying to access from below?

      Team PC

  73. Reply
    June 29, 2019 at 5:51 pm
    Tim Elmer

    I am installing suntuf roofing sheets on a pergola using one shot screws. I have noticed that a couple (so far) of the screw holes have developed a small radial crack during the drilling process. I am not sure what is causing this (too fast or too slow drilling? too much pressure?) however can these cracks be repaired, say with silicone, and if they can’t be repaired are they likely to propagate resulting in an unsightly, leaking sheet?
    kind regards
    Tim

    • Reply
      July 1, 2019 at 12:46 pm
      Polycarbonate Roofing

      Hi Tim

      Thanks for the question… not an easy one to answer via internet. There is a sweet spot with speed and pressure. A mid speed is generally good without too much pressure. You need enough speed to ensure that the cutter will still work and cut itself.

      Hope this provides some help?
      Team PC

  74. Reply
    July 1, 2019 at 1:36 pm
    Tim

    Thanks Team PC. Any options for repair of the ones that have occurred?
    Tim

    • Reply
      July 1, 2019 at 2:14 pm
      Polycarbonate Roofing

      Hi Tim

      Sorry, nothing that we can suggest in terms of repair… Did the washer cover the area?

  75. Reply
    July 1, 2019 at 3:23 pm
    Tim

    Two cracks. One is covered by the washer the other is not.

  76. Reply
    August 4, 2019 at 10:41 pm
    Brad

    Can you use polycarbonate roof to safely collect drinking water?

    • Reply
      December 10, 2019 at 7:49 pm
      Polycarbonate Roofing

      Hi Brad
      Thanks for your enquiry.
      While there is no adverse effects from the water collected off polycarbonate (i.e. leaching of chemicals) manufacturers will generally advise not to use due to other foreign items being on the roof i.e. bird droppings, dirt etc.
      Regards Team PCR

  77. Reply
    August 12, 2019 at 7:28 am
    Ant

    Hi,
    I need to install leafstopper aluminium gutter gaurd over some corrugated sheets on my pergola, what would be the best way to attach the saddles that hold the mesh to the sheets?
    The saddles are tech screwed to the colorbond sheets.

    Cheers

    • Reply
      August 20, 2019 at 1:34 pm
      Polycarbonate Roofing

      Hi Ant

      Maybe a stitching screw could be utilised? Someone will contact you with details.

      Team PC

      • Reply
        August 28, 2019 at 6:35 pm
        Ant

        Many Thanks.

  78. Reply
    August 12, 2019 at 9:53 pm
    Shannon Phillips

    Hi, I am turning my shed into a greenhouse and would like some recommendations on the best suntuf roofing if anyone can please help

    • Reply
      August 20, 2019 at 1:16 pm
      Polycarbonate Roofing

      Hi Shannon

      There are a few option. Most people will us the suntuf range of profile sheets as a cost effective way of doing this. Sometimes the sunlite can also be used – though more expensive. Thge main consideration is colour pending on what you are growing and how much light you need etc.

      Feel free to contact us if you want to talk about this more.
      Team PC

  79. Reply
    August 15, 2019 at 2:47 pm
    Don

    I have a pergola measuring 16′ 4″ by 15′ 2″. I recently replaced the original polycarbonate roofing (Suntuf) using 26 inch by 12 foot pieces. The roofing company used the 15 foot 2 inch side to lay the sheets longways. To cover the remaining 3 feet+ they cut 4 foot sections and placed them under the 12 foot sheets. This morning, we had rain and the roof leaked in a couple of areas. I noticed that Michael (November 23, 2016) had the same problem. I read the suggestions and wish I could use the 1st option. The slope is not the greatest. Question: Can I use Loctite PL Premium 10 fl. oz. Polyurethane Construction Adhesive to stop the leaks? OR is there another adhesive I can use?

    • Reply
      August 20, 2019 at 12:38 pm
      Polycarbonate Roofing

      Hi Don

      Thanks for the question. If I understand your message correctly, I think you have a similar – but different, problem to Michael. While we are not familure with that particular adhesive, the general advice would be NO. Polycarbonate sheets will need to expand and contract as they heat and cool so this is not recommedned. In Australia (i am also guessing that you are not from around here) we have a butyl rubber strip for waht we call end laps? maybe this is also available there? This rubber goes between the sheeets – but still allows them to move.

      I hope this is of some assistance for you.
      Team PC

  80. Reply
    August 29, 2019 at 12:20 am
    Sean

    What is the maximum distance I can space my rafters. I will be using clear corrugated sheeting.
    This is to cover a grow site, so I need as much light as possible, and accordingly don’t want to cast shade with the rafters.

    • Reply
      August 29, 2019 at 9:57 am
      Polycarbonate Roofing

      Hi Sean,

      Thanks for the question.

      Corrugated panels are installed on purlins, your maximum end span should be 800mm and maximum mid span 1000mm.

      Hope this helps.

      Team PCR

  81. Reply
    August 30, 2019 at 2:37 am
    Sean

    Can I grow plants under the clear corrugated sheeting?

    • Reply
      August 30, 2019 at 9:12 am
      Polycarbonate Roofing

      Hi Sean

      Thanks for the question. Yes, certainly. Infact clear polycarboante are used all over the world in commercial greenhouses. Depending on what you are growing, there are colours that diffuse the light if required.
      Polycarbonate greenhouse
      Greehouse green crops
      Polycarbonate Roofing  greenhouse Lettuce

      Thanks
      Team PC

  82. Reply
    September 6, 2019 at 1:46 pm
    Dan

    Hi – We have a detached pergola (used as a car park) that has a lattice “roof”. I was thinking of adding polycarbonate to keep the rain off. However, I’m discovering that to add the 5 degree drop, this will be more of a project than I realized. The pergola is about 7.3m x 7.3m. If I used NO drop, the “rafters” and “purlins” are already in place – but of course, leaves and dirt will collect on the polycarbonate. Other than needing to be sprayed off occasionally, would laying the polycarbonate flat be a real problem on a detached pergola that DOES NOT need to be truly weatherproof? (Lifetime of the polycarbonate, etc.). It also won’t look as nice, but may do the job… Thanks!

    • Reply
      September 12, 2019 at 10:30 am
      Polycarbonate Roofing

      Hi Dan,

      Thanks for the question! The are a couple of issues with having no pitch on your roof. As you’ve mentioned the leaves and dirt will collect on the roof as the wind and rain isn’t able to blow/clean them off regularly. Another problem is water will pool as it can’t run off and this can cause leaking or sagging of the panels. If you have a low pitch on your roof, regular cleaning is recommended. Installing the panels outside of the manufacturers guidelines may void your warranty.

      Many thanks
      Team PCR

  83. Reply
    September 20, 2019 at 5:47 pm
    Adam

    Hi there, I have to cut a hole for a downpipe which runs in one of high corners of the polycarbonate sheeting. What is the best way to seal around this downpipe to avoid water leaking through?

    • Reply
      October 14, 2019 at 3:59 pm
      Polycarbonate Roofing

      Hi Adam,
      Thanks for the question.
      You will need to use flashing to prevent leaking around the downpipe. If you are installing a profile panel such as corrugated you could use apron flashing with infills underneath or for a flat panel you could source a custom flashing from a local metal fabricator.
      Hope this helps.

      Team PCR

  84. Reply
    September 28, 2019 at 8:23 pm
    Alban Johnson

    Hi,

    I have a 5 degree corrugated polycarbonate roof over a swimming pool, and it is great! However the overlaps get dirty and are difficult to clean. Is there any solution? I was thinking maybe a bead of silicone to stop detritus and moisture getting between the sheets . But then this would make cleaning impossible, and besides I see you don’t recommend using silicone with polycarbonate. Any thoughts?

    Regards,
    Alban.

    • Reply
      October 11, 2019 at 12:38 pm
      Polycarbonate Roofing

      Hi Alban,

      Thanks for the question.
      You can use butyl rubber (which will be visible) between the overlaps and as mentioned it is generally not recommended to use silicone but if you do it needs to be neutral cure or non acidic.
      Hope this helps.

      Team PCR

  85. Reply
    October 15, 2019 at 4:20 pm
    Joe Purcell

    Hi, I am replacing my old fiberglass panels with Suntuf. The old panels are in the Greca format and I want to replace them with corrugated sheets. Will there be any issues with spacing or flashing? Joe

    • Reply
      December 10, 2019 at 7:53 pm
      Polycarbonate Roofing

      Hi Joe
      Thanks for your enquiry.
      You would need to check the purlin spans on your roof to make sure they are within the recommendations for corrugated sheets i.e. end spans 800mm max and mid spans 1000mm max. If you previously had a Greca profiled flashing then of course this would not fit Corrugated profile.
      Regards Team PCR

  86. Reply
    October 15, 2019 at 9:01 pm
    Craig

    Hi,
    I’m installing polycarbonate trimdek roofing – onto recently painted battens. The roofing area does not receive much sunlight so I do not expect too much movement in the sheets. I will use the Clearfix self-drilling screw. I’ve installed a number of additional battens such that they spaced very close together. My question is if I install anti-noice tape, is it ok that I just install it on every third batten rather than every single batten (which would be quite onerous)? Alternatively, I’m thinking of not using any tape at all.

    • Reply
      December 10, 2019 at 2:33 pm
      Polycarbonate Roofing

      Hi Craig
      Thanks for your enquiry. Polycarbonate does expand and contract and the amount of expansion will depend on the length of the sheet i.e. the longer the sheet the more expansion.
      To install purlin tape on every third batten would defeat the purpose of the tape so would be all or nothing.
      Purlin tape does help to eliminate the creaking noise as the sheet releases from the painted surface. It’s not a must just an option.
      Regards Team PCR

  87. Reply
    October 27, 2019 at 10:08 am
    Toque

    I am not planning any gutters with my patio roof. What is the maximum allowed overhang off the lowest purlin?

    • Reply
      December 10, 2019 at 8:37 am
      Polycarbonate Roofing

      Hi Toque
      Thanks for your enquiry. Maximum overhang will depend on what sheet you are using but the most common would be a maximum of 50mm past the last purlin.
      Thanks Team PCR

  88. Reply
    November 13, 2019 at 7:21 pm
    Rob Paratore

    Hi there
    I need to flash Greca profile sheets against a fibro gable and they will run with channels parallel to the wall rather out from it as I have seen in your diagrams. What is the best method of flashing in this case? Obviously I can’t use the apron flashing to fit into the channels, so I was wondering if I could use your barge capping to prevent leaks in this case?
    Regards
    Rob

    • Reply
      November 26, 2019 at 4:23 pm
      Polycarbonate Roofing

      Hi Rob,

      Thanks for the question.

      Unfortunately we don’t have a suitable flashing we can supply in this instance.
      You will need to source a custom flashing from a a sheet metal company in your local area.

      thanks
      Team PCR

  89. Reply
    November 20, 2019 at 7:24 am
    Corey Julian

    If using for vertical application (wall cladding) – what would be the max spacing for the fixings?

    • Reply
      November 26, 2019 at 4:13 pm
      Polycarbonate Roofing

      Hi Corey,

      Thanks for the question.

      It would depend on the product that you are using? Generally (in Australia) you can increase the roof spans by 10% for a vertical (wall) application.

      Thanks
      Team PCR

  90. Reply
    December 10, 2019 at 8:00 am
    DP

    Three quick questions:

    Context: I have a open air pergola with flat roof in warm weather (100 degrees fahrenheit or 38 degrees celcius) during summer. Planning to use the following roof panel.
    https://www.homedepot.com/p/Suntuf-26-in-x-6-ft-Polycarbonate-Roof-Panel-in-Sea-Green-173520/305320663

    1. What do you use for fall/slope, is it wood mostly or is there a ready made strip like below
    https://www.homedepot.com/p/Suntuf-24-in-Horizontal-Plastic-Closure-Strips-6-Pack-92770/100067957

    2. And what do you use the closure strips above for? Is it mainly to seal the sheet closer to wall/flash?

    3. I couldnt find Purlin tape on homedepot, not sure if its required for this type of panel.

    • Reply
      December 10, 2019 at 8:35 am
      Polycarbonate Roofing

      Hi DP
      Thanks for your enquiry. As you are in the State please contact
      US OFFICE
      Phone: 1-800-999-9459
      Address: 9735 Commerce Circle, Arcadia West Industrial Park Kutztown, PA 19530, USA
      Email: ContactUs.USA@palram.com
      Products and installation vary from country to country so you need to check with them.
      Regards Team PCR

    • Reply
      December 11, 2019 at 2:00 pm
      Polycarbonate Roofing

      Hi DP
      I can see from your enquiry you are located in the US.
      Please contact Palram Phone: 1-800-999-9459
      Address: 9735 Commerce Circle, Arcadia West Industrial Park Kutztown, PA 19530, USA
      Email: ContactUs.USA@palram.com
      for details as stock and installation varies from country to country.
      Regards Team PCR Australia

  91. Reply
    January 25, 2020 at 2:47 pm
    Garry

    Hi,

    What screws are best for fixing polycarbonate wall flashing to timber?

    Thank you,

    Garry.

    • Reply
      January 28, 2020 at 3:18 pm
      Polycarbonate Roofing

      Hi Garry

      Not sure what you mean by wall flashing – could this be an apron? – generally all polycarbonates will require an expansion hole. A OneShot screw will do this for you if you’re screwing through the rib/crest of the sheet. If you are screwing the pan or a flat part of the flashing you may require a standard screw with a EPDM washer – and PRE-DRILL a 10 mm oversize hole.

      Give us a call if this does not make sense.

      Thanks TEAM PC

  92. Reply
    January 30, 2020 at 7:39 pm
    Gary

    We have just replaced old (16yrs) and damaged polycarbonate roofing on our pergola. We have used 4.8m corrugated sheets with one shot screws. The fall on the pergola is just under 5 degrees and we noticed the previous installer had siliconed the overlap of the sheets. We have lived here for 6 years and up until recently there were no leaks in the roof, we could sit under in all weather. Recent hail storms changed that, hence replacement of the roof. We have fixed the sheets with a 1.5 corrugation overlap, on some sections the overlap is sitting up and there is a 5mm gap. It doesn’t appear that the screws have been over-tightened. Any suggestions to prevent water ingress other than to use silicone?

    • Reply
      January 31, 2020 at 9:22 am
      Polycarbonate Roofing

      Hi Gary

      Thanks for the question.

      A few things here:
      1. It may be worth checking that the screws have cut the sheet properly on the laps. The sheets should sit together well on the laps, where you have a 5mm gap makes us think that there has been a problem with the screw. I would check to make sure that the cutter has cut a clear hole in BOTH sheets and that the cutter itself is clear and not ‘pinning’ either sheet in the areas where you have the gaps. A screw that is not straight, or not been secured without enough speed may cause this…

      2. Silicon is not advised in these situations (as you have alluded to). Generally if you have a 5 degree fall and the laps look good, you shouldn’t have too much trouble. The best product to use if you are still concerned is a butyl rubber. The down side of this is that it is black and you will see it.

      We trust this helps!
      Regards
      Team PC

  93. Reply
    February 10, 2020 at 9:08 pm
    Abdelrahman Abdelrady

    Do you have a basic certified training for installation Panels and corrugated sheeting and cold store installation according to European code ?

    • Reply
      February 13, 2020 at 8:10 am
      Polycarbonate Roofing

      For any info for Europe please contact
      UK OFFICE
      Phone: +44 1302 380738
      Address: White Rose Way, Doncaster DN4 5JH, UK
      Email: palram@palram.com

  94. Reply
    February 11, 2020 at 2:54 am
    Ken

    We are considering a polycarbonate roof over an arbor under a number of large fir, pine and cedar trees. Should we be concerned about water dripping from the trees and bringing chemicals from the trees onto the roof?

    • Reply
      February 15, 2020 at 10:20 am
      Polycarbonate Roofing

      Hi Ken
      I have sent you an email with some info on cleaning and chemical resistance.

      Cheers PCR

  95. Reply
    February 17, 2020 at 7:12 pm
    G Bala Abhilash

    we are working on installation of 10mm Solid sheets but the parent material in 15mm thick section , i want to know screws that can go in to 10mm sheet and 15mm thick pipe , and hold together on top vertical open side ..?

    • Reply
      February 20, 2020 at 9:54 am
      Polycarbonate Roofing

      Hi Bala

      You will need to allow for expansion and contraction of the polycarbonate. In the case of screwing you would need to have an over-sized hole in the polycarbonate. If i understand your question correctly – you may need to look a a different method as you will not be able to hold them together this way.

      Regards
      Team PC

  96. Reply
    February 19, 2020 at 2:31 pm
    Jake

    I’m looking to replace my pergola roof with Suntuf poly sheets, the original roof butts up against the outside face of the gutter of the house and does not have flashing (just has a bead of silicone stopping leaks…)
    Can I install C-channel and foam on the end of the new poly and butt it up against the gutter? Will this be waterproof enough?
    Or should I install metal/poly apron flashing with foam underneath?
    Thanks.

    • Reply
      February 20, 2020 at 9:57 am
      Polycarbonate Roofing

      Hi Jake

      You could go either way,but the back channel (c section) is quite well suited to this situation. You could silicon the back channel to help waterproof.

      Regards
      Team PC

  97. Reply
    February 29, 2020 at 1:55 pm
    Brett

    Hi, I’m using corrugated polycarb sheets as a weather barrier around the back deck (i.e. as a wall, instead of a roof). In the gap between the roof beams and the deck rails, do I need to fix the overlapping sheets together somehow (like, with a rivet), or is that unnecessary? Thanks, Brett.

    • Reply
      March 2, 2020 at 3:06 pm
      Polycarbonate Roofing

      Hi Brett

      Generally this is not required. Rivets are not advised in any case as they do not allow room for expansions and contraction of the sheets. If you do require the laps to be pinned together a stitching screw is you best bet – you would need one specific to the application (to allow for previously mentioned expansion).

      I guess that you probably have a 1.0-1.4 m unsupported span? If so, this is probably a little over-spec for the sheets – the end spans should be no more than 800 mm… Though given its a wall you do have a 10% margin and probably less problems if your happy to push your luck!

      Trust that this helps.
      Team PC

  98. Reply
    June 3, 2020 at 10:08 am
    Chenee

    Hi we are putting a dark poly sheet over our decking. Can you advise if when standing on the deck would then look dull in colour of grey because of the darker sheet above. I am wondering if we should have a lighter sheet above for a more natural coloured light when using the deck but do need UV / heat protection

    • Reply
      June 4, 2020 at 4:00 pm
      Polycarbonate Roofing

      Hi Chenee

      Thanks for your enquiry.

      Yes a dark colour will darken the area. By using a lighter colour it will reflect the natural light and look brighter.
      All the colours (including Clear) provide 99.9 UV protection. But the actual colour of the sheet allows different amounts of light and heat trasmission so if you look at the brochures under the colour range chart it tells you what those figures are for both light and heat.

      Regards Team PCR

  99. Reply
    July 23, 2020 at 9:27 am
    Arek

    Hi there,

    Ill be installing a few plycarb twin wall panels to extend and existing colour bound roof. Since the exisitinfroof has its own metal fascia and a gutter, would in general installers mount the end alliminium cap to the metal fascia directly or is there a metal plate of some sort that is used as an intermediate support ?
    Ill be putting 6 panels on 1m spaces wodden rafters.

    Thanks

    Arek

    • Reply
      August 4, 2020 at 10:27 am
      Polycarbonate Roofing

      Hi Arek

      Thanks for the question.

      Generally the end caps shouldn’t be fixed to the fascia. They sheets will be secured to the Rafter through the HBARs. Then flashings should be used for waterproofing.

      Team PC

  100. Reply
    July 25, 2020 at 6:40 am
    Peter

    Hello poly roof experts,
    I’m laying out the framing for a 26×5 (feet) Suntuf canopy at a 14+ degree pitch alongside our house and plan to use the polycarbonate Suntuf wall connector (apron?) with the horizontal lap siding on the house. In order for the connector/flashing to fit correctly, what is the required distance between ridge plate and the lower edge of the siding? Any pointers for installation of the wall connector would be appreciated.

    • Reply
      August 4, 2020 at 10:35 am
      Polycarbonate Roofing

      Hi Peter

      Please see attached images. I suspect that these will assist with your query, though Im not sure what you are trying to ask… sorry.

      These are set size option. In some circumstance you may find it easier to have something bent up at a local sheet metal fab. To suit exactly what you need.
      Corrugated Wall Flashing APRON
      APRON flashing angle
      APRON flashing height
      APRON FLAHING tail length

  101. Reply
    August 5, 2020 at 11:15 am
    Warren

    I have just installed new roofing sheets with a 5 degree fall, it appears that when it rains the water will leak and it appears that it leaks at all of the joints, it seems like it gets sucked under the joints. is this possible ?

    • Reply
      August 6, 2020 at 8:46 am
      Polycarbonate Roofing

      Hi Warren

      Thanks for your enquiry. Can you let us know what type of sheet you have installed i.e. a profiled sheet (corrugated) or a twinwall/multwall?
      Thanks Team PCR

  102. Reply
    August 15, 2020 at 9:57 am
    Dianne Beltrame

    Hi we want to use the Suntuf Ez-Glaze on a pitched roof, what do you use for a ridge capping?

    • Reply
      August 15, 2020 at 4:56 pm
      Polycarbonate Roofing

      Hi Dianne
      We can supply foam infills for the Ez Glaze and then you can either use a polycarbonate ridge flashing (which we can supply) or a normal colourbond ridge (which you would need to get from a metal supplier).
      The infills will sit in-between the sheet and the ridge to stop the wind blowing any rain back up under the capping.
      Regards Team PCR

  103. Reply
    September 4, 2020 at 2:39 pm
    joe

    unlike corrugated polycarbonate sheets trimdek has a fairly flat ridge, do they need special flat neoprene washers unlike the standard washers that have the corrugated profile? I ask because I used the latter washers and as they are not fully flat they somewhat distort the poly if too tight and seems to have gaps if too loose. I’m noticing a bit of buckling in places (all have 10mm expansion holes) Please advise

    • Reply
      September 8, 2020 at 11:12 am
      Polycarbonate Roofing

      Hi Joe
      Thanks for your question. The washers supplied with the One Shot or Clearfix screws are the same regardless of profile. If the sheets are buckling, especially on the overlaps, I would suggest you check to make sure the cutter has drilled through both sheets, not just the top sheet. The other thing to check would be the screws are not on an angle. And yes it is a fine line of not screwing down to tight or too loose.
      Regards Team PCR

  104. Reply
    September 29, 2020 at 7:56 pm
    Lynn

    Hi there,

    How do you secure the infills at the front of the Greco profile roofing to get a snug fit? Given the flexible nature of the foam, I’m assuming you can’t screw through the foam. On the other hand I assume you can’t glue them to the roofing thereby inhibiting the expansion capability of the sheeting. Any suggestions? I couldn’t draw a conclusion from the image on the installation guide.

    Thanks.

    • Reply
      October 19, 2020 at 11:14 am
      Polycarbonate Roofing

      Hi Lynn
      Thanks for your enquiry. Normally you would screw through the infill when installing the sheet.
      You could glue the INFILL to the FRAME but never to the sheet itself.
      Hope this clarifies for you.
      Regards Team PCR

  105. Reply
    October 2, 2020 at 10:14 am
    Peter Weir

    Hi do you make the profiled apron flashing for the Trimdeck sheets?
    Thanks
    Pete

    • Reply
      October 3, 2020 at 1:50 pm
      Polycarbonate Roofing

      Hi Pete
      No unfortunately there is no profiled flashing for Trimdek profile. You would need to use a colourbond flashing and either scrib it or we do have the foam infills that you could use to seal between the sheet and apron flashing.
      Regards Team PCR

  106. Reply
    December 10, 2020 at 12:32 pm
    Minhly Ngothai

    Hello,
    I am planning to install the twinwall polycarbonate on my pergola with the area of 16m2. I already have the 2.4x1m twinwall polycarbonate sheets and I know how to connect the width 1m with another 3 sheets of 1m using the H- connector. However since my sheets are only 2.4m long and not 4m long, my question is how do I connect the 2.4m sheet length with another sheet to make up to 4m in length? Looks like I can’t use H connector as the water will be trapped here. Can you please advise how I can connect another sheet that runs down the gutter?
    Thank you

    • Reply
      December 28, 2020 at 11:25 am
      Polycarbonate Roofing

      Hi thanks for your enquiry. Unfortunately you cannot join twinall sheets in length. As you have pointed out the water would be trapped where the join is.
      You would need to purchase 4m long sheets.
      Regards Team PCR

  107. Reply
    December 12, 2020 at 9:25 pm
    Andrew

    hi trying to replace damaged 5 rib polycarbonate roof on patio just wanting to know the best way to get in between the tin roof and the timber batton.

    • Reply
      December 29, 2020 at 9:45 am
      Polycarbonate Roofing

      Hi Andrew
      To access the sheets you will need to use a ‘crawl’ board – a plank of somesorts – put across the sheets to spread your weight. You should never walk directly on the polycarbonate sheets. You can then unscrew the damaged sheets and replace.
      Regards Team PCR

  108. Reply
    December 31, 2020 at 9:26 am
    graeme mcnicholl

    Hi. Currently have old greca installed and want to replace with corro. It is a simple curved roof. Chord 3600. Height 500. Need to know sheet lengths please. Is it long enough to curve? Is greca or corro better for curving?

    • Reply
      January 10, 2021 at 8:00 pm
      Polycarbonate Roofing

      Hi Graeme
      Thanks for your enquiry. Corrugated and greca have the same cold curving radius which is a minimum 4m. If the chord is 3.6m and the rise .5m then this is actually outside of the miniumum radius at approx 3.5m so would void warranty on the sheet. Over a chord of 3.6m the maximum rise would be .42m to be within guideines.
      Regasrds Team PCR

  109. Reply
    January 12, 2021 at 4:30 pm
    Callan Rose

    G’day, is it possible to curve a flashing? We have a curved section over our front door which is currently covered by (what looks like) perspex. It is in need of replacement and I think it’ll be easy enough to lay a sheet of polycarbonate lengthways over the existing frame. One end of the sheet will need to connect to a brick wall. Currently the gap between the edge of the perspex and the brick is filled with silicon – it’s OK but not ideal. Any suggestions would be appreciated.

    • Reply
      January 24, 2021 at 12:12 pm
      Polycarbonate Roofing

      Hi Callan
      We only supply polycarbonate flashings in ridge, barge or apron so these would not be suitable for you.
      You may need to get a colourbond flashing curved to suit the application.
      Or if you decide to use silicone just make sure it is a neutral cure/non-acidic so it doesn’t damage the polycarbonate sheet.
      Regards Team PCR

  110. Reply
    January 29, 2021 at 10:53 am
    Maurice Micallef

    I have an alfresco roof section of poly carb sheets in a gable arrangement, ever since the Melbourne golf ball hail damage of Christmas day 2011, having had all the poly carb and clear ridge cappings replaced under my home insurance, the section of poly carb roof leaks when it rains around the ridge line areas.
    The clear ridge capping is a flat style profile, I am of the opinion the water is making its way under the ridge capping and working its way down along the underside of the roof sheets
    Is there a way I could rectify this problem?

    • Reply
      January 29, 2021 at 2:24 pm
      Polycarbonate Roofing

      Hi Maurice

      I believe that you require an infill. It is a closed cell foam that sits between the flashing and the roofing for waterproofing. We will need to know what profile sheeting you have, contact us at sales@polycarbonate.com.au and we can assist further.
      Thanks
      Team PC

  111. Reply
    February 1, 2021 at 7:26 am
    Steve Martin

    Hi there, I’m in Canberra, can you tell me where I can purchase the ridge capping in Greca solar grey? I have purchased the sheeting but can’t find the capping in this colour. Thanks
    Steve

    • Reply
      February 1, 2021 at 9:13 am
      Polycarbonate Roofing

      Hi Steve
      Thanks for your enquiry.
      Unfortunately Ridge cap in Grey is not available. The only option in the polycarbonate is Clear or you can use a standard Colourbond one if you prefer (which we do not supply).
      Regards Team PCR

  112. Reply
    February 24, 2021 at 8:14 pm
    David Birrell

    Hi guys,
    How do you recommend installing flashing around corners?
    I have a square column which the corrugated sun turf has been installed around.
    The installers just used silicon but it has deteriorated, is looking shoddy, leaking and I need to make it water tight again.
    Many thanks

    • Reply
      February 26, 2021 at 12:09 pm
      Polycarbonate Roofing

      Hi David

      Thanks for the question. If I am understanding you correctly – the best way to do this would be with APRON FLASHING and or a PAN flashing (up hill of the column).

      You will need to get something bent up to suit.

      Thanks
      Team PC

  113. Reply
    February 25, 2021 at 9:10 am
    lindsay hoffman

    i have a 4 mr long wooden wall running alongside my pool. The wall has almost reached its use-by date and i am thinking of replacing it with a steel framed wall clad with either colorbond sheeting or suntuf sheeting which is the preferred option. I read that the uv protection is only on one side of the suntuf sheeting. Does the other side of the sheeting need some sort of protection from the sun?

    • Reply
      February 25, 2021 at 9:34 am
      Polycarbonate Roofing

      Hi Lindsay

      Thanks for the question. You are correct, some polycarbonate sheets only have protection from UV on one side. This means that if you expose the non-protected side to UV it can cause the sheet to breakdown prematurely. This can happen with walls or where UV reflects off another surface. Generally all ‘profiled’ sheets (Corrugated, greca or trimdek) are UV1 (one sided protection), most twinwall, multiwall and solid sheets are UV2 (both sides protected).

      Trust this helps
      Team PC

Leave Comment

Cancel reply

Your email address will not be published. Required fields are marked *


clear formSubmit

  • Domestic Polycarbonate Roofing
    • Suntuf
    • Laserlite
    • Sunsky
    • Beehive
    • EZ-Glaze
    • Sunlite Twin Wall
    • Laserlite Multiwall
    • Makrolon Twin Wall
    • Sunpal Multiwall
    • Danpalon Domestic
    • Sunglaze Polycarbonate
    • Durashield Domestic
  • Commercial Polycarbonate Sheeting
    • Suntuf Industrial
    • Suntuf Plus
    • Sunpal Multiwall
    • Sunglaze Architectural System
    • Danpalon Commercial
    • Makrolon – Solid Sheet
    • Lexan – Solid Sheet
    • Durashield Commercial
  • Metal Insulated Sheeting
Call now on 1800 506 454 or Get a quote today

Products

Polycarbonate
Laserlite ®
- Laserlite 2000+
- Laserlite 3000
-Makrolon
-Makrolon Twinwall

- Solid Sheet
Danpalon ®
- Danpalon
 
Suntuf ®
- Suntuf Domestic
- Suntuf Industrial
- Suntuf Plus
-Sunpal
-Sunlite
-Sunglaze
PVC
Durashield ®
Metal Insulated Sheeting
Solaris

Contact Us

Email us at
sales@polycarbonate.com.au
51 Steel St Capalaba Qld 4157
Monday - Thursday 8.30am - 4.30pm
Friday 8.30am - 2.30pm
Saturday, Sunday & Public Holiday Closed
© Polycarbonate Roofing 2014 - Roofing suppliers Brisbane Queensland, Sydney New South Wales, Melbourne Victoria, Adelaide South Australia, Perth Western Australia, Darwin Northern Territory | Polycarbonate Roofing | Insulated Patio Roofing